SpotCell™ Automatic Dialer System
Overview
All SpotCell adaptive repeaters now come
equipped with built-in alarming capabilities
which have been designed to be compatible
with industrial-grade alarm monitoring
equipment as well as standalone auto-dialers.
This provides immediate SpotCell alarm
notification to remote users using a regular
telephone line.
The alarming interface consists of a solid-
state, low voltage, optically isolated, form 'B'
type contacts (i.e., normally closed / open on
alarm). The form 'B' fail-safe type
configuration enables alarms to be tripped in
case of power failure in addition to fault
conditions.
The following outlines the general steps
required to configure the SpotCell automatic
dialer system. This is followed by appendices
describing specific automatic dialer systems.
Figure 1- Auto Dialer Connection Diagram
Configuration requires connection from the
SpotCell coverage unit (CU) to the auto dialer
and from the auto dialer to the telephone wall
jack.
Required Cables
1. RJ45 to 2 wire cable (CU to auto dialer
connection)
Note: The two wires are 5 and 6 of the RJ-
45 cable (figure 2)
Figure 2- RJ-45 cable
2. RJ11 cable (auto dialer to telephone jack
connection)
Connection Details
1. Connect the RJ45 cable to the CU.
2. Connect the 2 wires to the appropriate
sensor input channel on the auto dialer.
Note: For information on sensor input
channels, see specific auto dialer product
documentation.
3. Using the RJ11 cable, make a
connection from the “Tel IN” jack of
auto dialer to the wall jack
Note: The PSTN connection can also
be hardwired; see specific auto dialer
product documentation.
4. Connect power to the auto dialer
The auto dialer must now be programmed
(see appendices). Once the auto dialer is
programmed, an alarm generated by the
SpotCell CU will result in the programmed
number(s) being dialed.
Alarm Conditions
The following will produce an alarm condition
on the SpotCell CU:
Power alarms: power failure, hardware
failure.
Spectrum alarms: low RSSI, high RSSI and
high adjacent signal.
Page view 0
1 2 3 4 5 6

Summary of Contents

Page 1 - Alarm Conditions

Spotwave Wireless Inc. 1 Hines Road, Suite 204, Ottawa ON

Page 2 - Configuration

Spotwave Wireless Inc. 1 Hines Road, Suite 204, Ottawa ON

Page 3 - Spotwave Wireless Inc

Spotwave Wireless Inc. 1 Hines Road, Suite 204, Ottawa ON

Page 4

Spotwave Wireless Inc. 1 Hines Road, Suite 204, Ottawa ON

Page 5 - Sample Program Planner

Spotwave Wireless Inc. 1 Hines Road, Suite 204, Ottawa ON

Page 6 - Program Planner Sheet

Spotwave Wireless Inc. 1 Hines Road, Suite 204, Ottawa ON

Comments to this Manuals

No comments