N.C./N.O. DRY CONTACT ACTIVATION HOOKUP
PP
-
1
STANDBY
BATTERY
(optional)
PANEL OR SENSOR
NC, NO, MOMENTARY, OR
CONTINUOUS ALARM
ACTIVATION
12VDC
+
-
ALARM
RED
BLACK
YELLOW
WHITE
RED
GREEN
TEL LINE
Make sure unit is set to “OFF” prior
to wiring and phone line hook-up.
Notes:
1. In momentary mode the dialer automatically dials all numbers
even after the alarm input is restored to non-
alarm. To stop dialing
you must press the M button to switch the unit to the OFF mode.
2. In continuous mod
e the alarm condition must be maintained for
the dialer to complete it’s dialing cycle (typically 7 minutes).
Dialing stops when the alarm input is restored to non-
alarm or by
pressing the M button.
3. Match the power cables colored wires to the corresponding
outputs on the alarm panel. Do the same for the telephone cable.